Show simple item record

dc.contributor.authorKiatsookkanatorn, Paiboonen_US
dc.contributor.authorไพบูลย์ เกียรติสุขคณาธรen_US
dc.contributor.authorKlamrak, Passawiten_US
dc.contributor.authorภาสวิชญ์ กล่ำรักษ์en_US
dc.contributor.authorYindeeyom, Narongriten_US
dc.contributor.authorณรงค์ฤทธิ์ ยินดียมen_US
dc.contributor.authorWatjanatepin, Napaten_US
dc.contributor.authorนภัทร วัจนเทพินทร์en_US
dc.date.accessioned2023-03-28T07:11:38Z
dc.date.available2023-03-28T07:11:38Z
dc.date.issued2023-03-28
dc.identifier.issn2651-1096
dc.identifier.urihttp://repository.rmutp.ac.th/handle/123456789/4008
dc.descriptionวารสารวิชาการและวิจัย มทร.พระนคร, ปีที่ 16, ฉบับที่ 2 (ก.ค.-ธ.ค. 2565), หน้า 113-126en_US
dc.description.abstractThe trend of energy savings has been widely interested and phase shift transformers (HMT) have been extensively used. This paper presents the investigation of the effect of harmonic currents on losses of the HMT. In this paper, a 15-degree HMT with quad secondary winding is applied to find the relationship between harmonic currents and losses of the HMT. This relation can be met by testing the active power of primary and secondary sides while the HMT supplies for two and four non-linear loads at 25%, 50%, 75%, and 100% rated currents, respectively. The results reveal that harmonic currents affect winding eddy current losses significantly and the losses for loading the two secondaries 1 and 2 are the same as loading the two secondaries 1 and 3 while both %THDi are different. However, for loading the secondaries 1 and 2, the %THDi is more than 15% so it is not met IEEE 519 Std. while the HMT is supplied with four loads, the %THDi has met IEEE 519 Std. and the losses are less than 57% compared to one load. As a result of these, if the HMT is applied to an adjustable speed drive system, it is not only reduced the harmonics but also saved the energies.en_US
dc.description.sponsorshipRajamangala University of Technology Phra Nakhonen_US
dc.subjectElectric transformersen_US
dc.subjectหม้อแปลงไฟฟ้าen_US
dc.subjectPower Qualityen_US
dc.subjectคุณภาพกำลังไฟฟ้าen_US
dc.subjectHarmonics (Electric waves)en_US
dc.subjectฮาร์มอนิก (คลื่นไฟฟ้า)en_US
dc.titleInvestigation of the effect of harmonic currents on losses of phase shifting transformers and its realization using a 15-degree phase shifting transformeren_US
dc.title.alternativeการศึกษาผลของกระแสฮาร์มอนิกส์ต่อค่าสูญเสียของหม้อแปลงไฟฟ้าเลื่อนเฟสและการทำให้เป็นจริงด้วยหม้อแปลงไฟฟ้าเลื่อนเฟส 15 องศาen_US
dc.typeJournal Articlesen_US
dc.contributor.emailauthor[email protected]en_US
dc.contributor.emailauthor[email protected]en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record